ENUGU STATE UNIVERSITY OF SCIENCE AND TECHNOLOGY ESUT
DEPARTMENT OF ELECTRICAL/ELECTRONICS ENGINEERING
SECOND SEMESTER EXAMINATION 2011/2012 SESSION
ADVANCED ELECTRICAL POWER SYSTEMS ANALYSIS (EEE 772) MASTERS CLASS
TIME: 1Hr 30Min (Answer All Questions)
NB: IF you have not done any continuous assessment, write down what you have learnt in about 120 words first.
Basic Concepts
What is
modeling? How are managerial decisions made based on Electrical Power System
Analytical Results? What is Symmetrical Components and what is it used for? How
are assumptions made and what are the consequences of these assumptions?
Explain the procedure for fault analysis and use an example of an unbalanced
fault to illustrate this procedure. How would you develop a software for Load
Flow analysis using the Newton Raphson method. Illustrate your work with a flow
chart. Develop the Newton Raphson iterative method of Load Flow Analysis. Carry
out a comparative analysis between the Newton Raphson iterative method and the
Gauss Seidel Method and explain under what condition each method is preferred.
How is noise accounted for in State Estimation in the Electrical Power System?
Application
What is
generation mix? What is the national grid. The power utility in the country is
being privatized. What are the technical challenges associated with this
exercise. How can you ensure that Power delivery is optimized? What measures
must be put in place to ensure that the industry is properly regulated. Make a
workable proposal for a privatized Electrical Power System. How would this
system work? How would you ensure that the entire system is properly managed?
How would Electrical Power be produced and delivered to the intended users? How
would your knowledge of this course help you in your work? What is the
relevance of Electrical Power Systems Analysis in all this? How can you monitor
the quality of Electrical Energy being produced and delivered by each
Electrical Power Utility Company. What tariff options do you propose and why?
How can a fair and sustainable tariff structure be achieved? Maintenance is important
for effective Electrical Power Delivery. What are distributed parameters? Develop the
model of a long line.
Calculations
What is the
difference between the first swing and the multi swing transient stability
problems? How are they tackled analytically? Develop the swing equation. What
is the swing equation and what is it used for? What is the critical clearing
angle and what is its relevance? What is the relationship between the critical
clearing angle and the critical clearing time?
The
transmission line in the figure below is 200km long and a 132kV line of the
phase symmetric type. Given the data below, determine the voltage at Bus 2
given that R = 0.72 Ω/km, ωL=0.527Ω/km, 1/ωC = 0.425MΩ/km